Clear-Com HXII-KB-X4 HelixNet HKB 4-Gang Flush-mountable 2/4 Channel Speaker Station for 4-Pin XLR-M Headsets - PoE

ITEM #: CLCM-HXII-KB-X4 MFG #: HXII-KB-X4

Primary Image
  • Product Image Thumbnail 1 of 3
  • Product Image Thumbnail 2 of 3
  • Product Image Thumbnail 3 of 3
Free Shipping with $49 Minimum Order

Our Price:

$1,980.00

Availability: Usually Ships in 5-14 Days.
Please Email, Chat or Call (800) 522-2025 for Detailed Delivery Info
iAvailability Description Popup


HXII-KB-X4 - Overview

The HelixNet Speaker Station HXII-KB is a 4-gang flush-mountable user station with four channels over two shift pages hosted by the Arcadia® Central Station or HelixNet main station.

User Station
This innovative front panel user station provides two keysets assignable to any intercom channel to each of the two pages, which the user can toggle between for a total of four channels. The station's displays can be swiveled for optimal viewing angle. The user station is provided with a headset connection, gooseneck mic connector, loudspeaker and Program Audio level controls. HelixNet Speaker Station can be mounted in a standard 4-gang electrical enclosure or the optional Speaker Station enclosure (HXII-MOUNT, S-MOUNT) for portable and desktop applications. The X7 variant of the speaker station provides seven-pin headset connection with additional PTT GPI, assignable to user station keys.

HelixNet System Hosts
Arcadia: Supports up to 128 HelixNet User Stations over Ethernet or Powerline via the HXII-DPL Powerline Device. Up to 24 Channels can be HelixNet Enabled using a Licensed Port for assignment to any HelixNet User Station keyset.

HMS-4X: Supports up to 64 endpoints (Remote Stations, Speaker Stations, Beltpacks, HLI-2W2, HLI-4W2, LQ port). User stations can connect directly to the 2 HMS-4X Powerlines or via optional HLI-ET2 module using HXII-DPL Powerline Device or 3rd party network switch connection. HMS allows use of 12 channels which can be expanded to 24 using optional license.

  • Features:

    • Easy to use front panel with OLEDdisplays & backlit keys
    • Headset or hands free support with speaker and mic
    • 2 Keysets assignable to channels
    • Shift page for 4-channel operation
    • Program Audio level control
    • Display swivels for optimal viewingangles
    • Ethernet Network port with PoE
    • Powerline terminal plug
    • 4-gang for flush mounting
    • Optional enclosure for desktop use
    • Wired Partyline - Networked
    • Hosted by Arcadia or HMS-4X
    • Up to 24 Channels - Licensed
    • Up to 64 or 128 HelixNet Endpoints
    • Program Audio user level control
    • Easy to use CCM browser configuration
    • Fast front panel control & configuration
    • Central discovery & pairing on Arcadia
    • Plug-and-go Powerline to HMS-4X(2/3)
    • Central firmware upgrades from host
     
  • Specifications:

    • Connectors
    • Powerline: Powerline, Terminal Block 5 pole, 5mm pitch
    • Ethernet/PoE: RJ45
    • Headset: 4-pin XLR-M or 7-pin XLR-M with (2) PTT GPI (-X7)
    • Gooseneck Mic: 3-pin Tuchel
    • Power Connector: Terminal Block 2 Pole, 5mm

      Microphone Pre-Amplifier
    • Headset Mic Impedance: 200Ω (Dynamic)
    • Headset Mic Voltage: 1.7V (Electret selectable)
    • Limiter: +23dB
    • Route to Four-Wire Output at 0dBu Out:
      - Mic Gain: 60dB (Dynamic), 45dB (Electret)
      - Frequency Response: 300Hz - 10 kHz &Plusmn; 3dB, contoured for intelligibility
      - Distortion: <0.1% THD @ 1kHz
      - Noise: <-65dBu
      - Headphone Limiter: 0dB (selectable)

      Headphone Amplifier
    • Load Impedance: >32Ω
    • Output Level: +12dBu before clipping
    • Sidetone: -12dB (selectable)
    • Route From a Four-Wire Input at 0dBu In:
      - Max Gain: 0dB
      - Frequency Response: 40Hz - 10kHz &Plusmn;3dB
      - Distortion: <0.1% THD @ 1kHz
      - Noise: -65dBu
      - Headphone Limiter: 0dB (selectable)

    • Loudspeaker Amplifier
    • Load Impedance: 8Ω
    • Output Level: +18dBu before clipping
    • Route From a 4-Wire Input at 0dBu In:
      - Max Gain: 18dB
      - Frequency Response: 200Hz - 10kHz &Plusmn;3dB
      - Distortion: <0.1% THD @ 1kHz
      - Noise: <-50dBu

      PoE - Power over Ethernet
    • IEEE 802.3af-2003 - Class 0
    • PSE: 15.4W DC max @ Power Source Req.
    • PD: 12.95W DC max @ Powered Device Draw
      Note: HelixNet Speaker Station must be earthed to a clean ground when PoE is used. Preferably with the screen of a sheilded CAT5/6 cable.

      Powerline
    • Input Voltage: &Plusmn;29.5V DC
    • Input Current (Speaker Off): 0.3A
    • Input Current (Max): 0.5A
    • Powerline Utilization:
      - Speaker Station (Local Power) = 1 beltpack
      - Speaker Station (Speaker Off) = 2 beltpacks
      - Speaker Station (Speaker On) = 3 beltpacks

      Environmental
    • Operating Temperature: 32°F - 113°F (0°C - 45°C)
    • Humidity: 90% relative humidity

      Physical
    • Dimensions (HxWxD): 4-Gang NEMA, 4.5" x 8.2" x 2.4" (114mm x 209mm x 61mm)
    • Weight: 0.94lbs (0.43kg)
     
  • Item Includes:

    • 4x 6-32 x 1/2" mounting screws
    • 4x Screw cover
    • 1x Terminal block connector for powerline
    • 1x Terminal block connector for DC power
     

HXII-KB-X4 - Required Accessories