DPA 4011ER d:dicate Cardioid Microphone with Active Rear Cable

ITEM #: DPA-4011ER MFG #: 4011ER

Primary Image
Free Shipping with $49 Minimum Order

Our Price:

$1,980.00

Availability: Usually Ships in 5-14 Days.
Please Email, Chat or Call (800) 522-2025 for Detailed Delivery Info
iAvailability Description Popup


4011ER - Overview

This condenser microphone is renowned in recording studios and live applications around the world as an exceptional mic. State-of-the-art components have been carefully selected to provide optimal neutrality, accuracy and extremely low distortion.

The principal appeal of the 4011 Cardioid Mic is its directional quality and attention to detail. This mic makes everything sound like the original. The first-order cardioid pickup pattern provides superb separation between sound sources. It is equally suitable for close-up work on acoustic guitar, grand piano, overheads, percussion, wind instruments and vocals as it is for spot-miking symphonies. It can handle incredibly high sound pressure levels (SPLs).

Ideal for unobtrusive spot miking, such as hanging or table use, this mic is an ultra-compact cardioid microphone. The mic has a length of only 3.5 cm (1.4 in) and a low-key appearance.

This solution features an integrated cable solution with either side (4011ES) or rear (4011ER) cable entry. This allows the mic to be hung from the ceiling and create precise and repeatable positions and angles when spot miking orchestra sections or ambience atmospheres.

  • Features:

    • Ultra-compact spot or hanging mic
    • Close-miking
    • Great for high sound pressure levels
    • Accurate sound
    • Colorless sound
    • Modular flexibility
     
  • Specifications:

    • Directional pattern: Cardioid
    • Principle of operation: Pressure gradient
    • Cartridge type: Pre-polarized condenser
    • Frequency response: 20 Hz - 20 kHz
    • Effective frequency range: ±2 dB, at 30 cm (11.8 in)40 Hz - 20 kHz
    • Sensitivity: nominal, ±2 dB at 1 kHz10 mV/Pa; -40 dB re. 1 V/Pa
    • Equivalent noise level, A-weighted: Typ. 18 dB(A) re. 20 æPa (max. 20 dB(A))
    • Equivalent noise level, ITU-R BS.468-4: Typ. 25 dB (max. 27 dB)
    • Distortion, THD < 1%: 136 dB SPL RMS, 139 dB SPL peak
    • Dynamic range: Typ. 121 dB
    • Max. SPL, THD 10%: 144 dB SPL peak
    • Rated output impedance: 100 Ω
    • Minimum load impedance: 2 kΩ
    • Cable drive capability100 m (328 ft)
    • Output balance principle: Impedance balancing
    • Common mode rejection ratio (CMRR): > 40 dB
    • Power supply (for full performance): P48 (Phantom Power)
    • Current consumption: 3.5 mA
    • Connector: XLR-3M. Pin 1: shield, Pin 2: signal + phase, Pin 3: - phase
    • Color: Matte black
    • Weight: 109 g (3.8 oz)
    • Microphone diameter: 19 mm (0.75 in)
    • Capsule diameter: 19 mm (0.75 in)
    • Microphone length: 35 mm (1.38 in)
    • Maximum output voltage, RMS: 2.2 V
    • Polarity: +V at pin 2 for positive sound pressure
    • Temperature range: -40°C to 45°C (-40°F to 113°F)
    • Relative humidity (RH): Up to 90%
    • Matching tolerance (frequency response and sensitivity): ±1 dB
    • Phase deviation for kit: < 10°
     
  • GTIN:

    5713055006266
     

4011ER - Required Accessories

California Residents:
WARNING:
Cancer and Reproductive Harm - www.P65Warnings.ca.gov