EMS1250UL - Overview

Tripp Lite's EMS1250UL inverter with integrated charging system provides automatic, uninterruptible DC-to-AC power for critical on-board equipment. Ideal for installation by ambulance/EMS vehicle manufacturers, dealer or EMS service for OEM, replacements and upgrades. Supplies up to 1250 watts of continuous 120V AC power to 2 AC outlets from any 12V battery or automotive DC source. When AC cable is connected to a shore power source, commercial power passes through to connected equipment and the battery set is recharged via 3 stage, 14/55 amp selectable charging system. This unit can also function as a UPS system, responding to blackouts and voltage fluctuations with a near instantaneous automatic transfer to battery-derived AC output. Convenient Anderson DC input quick connector on the unit with extra Anderson DC input connector included in the box (user supplies batteries and cabling). Reliable large transformer design with efficient PWM sine wave output and frequency control powers resistive electronic loads or large inductive motors, compressors and other items with high current needs on startup. Included APSRM4 wired remote power switch with full status LEDs provides remote power inverter on/off switching and continuous status information (APSRM4 included). Supports an unlimited amount of runtime with any number of user-supplied batteries connected. Highly adaptable to a variety of applications and site conditions with adjustable charger settings for wet/gel battery types and selectable line to battery power transfer voltages. Includes AC input surge suppression. Includes hospital grade plug and outlets with GFI (ground fault interrupter) protection. TUV tested to UL458 (mobile inverter) and CAN/CSA-C22.2 No. 107.1-01. Meets GSA ambulance specification KKK-A-1822. NOTE: To protect against high current draw that may occur during inverter failure, a fuse link rated at 200a should be positioned no more than 18" from the EMS1250UL's battery in the positive line.

  • Features:

    • EMS1250UL serves as an automotive or stationary DC-to-AC inverter with automatic line-to-battery transfer and integrated battery charger
    • Supports 120V AC output from a 120V AC line power source or 12V DC battery source
    • 16.6 millisecond automatic transfer between line and battery power supports UPS protection during blackouts and voltage fluctuations for equipment compatible with a one cycle transfer time
    • 1250 watts continuous AC output in inverter mode, 1440 watts continuous AC output in AC mode
    • Double Boost inverter output supports momentary startup loads up to 200% of the continuous rating for up to 10 seconds
     
  • Specifications:

    • Style Heavy-duty with built-in battery charger
    • Frequency Compatibility 60 Hz
    • Output Receptacles (2) 5-15R
    • Output (Watts) 1250
    • Continuous Output Capacity (Watts) 1250
    • Peak Output Capacity (Watts) 2500
    • Output Nominal Voltage 120V
    • Output Voltage Regulation LINE POWER (AC): Maintains 120V nominal sine wave output from line power source. INVERTER POWER (AC): Maintains PWM sine wave output voltage of 120 V AC (+/-5%).
    • Output Frequency Regulation 60 Hz (+/- 0.3 Hz)
    • Overload Protection Includes 12A input breaker dedicated to the charging system and 12A output breaker for AC output loads
    • Outlet Details 2 Hospital-Grade GFCI duplex outlets
    • Nominal Input Voltage(s) Supported 120V AC
    • Recommended Electrical Service DC INPUT: Requires 12VDC input source capable of delivering 127A for the required duration (when used at full continuous capacity - DC requirements increase during Over-Power and Double-Boost operation). For automotive applications, professional hardwire
    • Maximum Input Amps / Watts DC INPUT: Full continuous load - 127A at 12VDC. AC INPUT: 32 amps at 120VAC with full inverter and charger load (11 A max charger-only / combined input load to support charger and AC output is automatically controllable to 66%-33%-0% based on AC output lo
    • Input Connection Type DC INPUT: 175A Anderson DC connector. AC INPUT: NEMA 5-15P hospital-grade input plug
    • Voltage Compatibility (VAC) 120
    • Voltage Compatibility (VDC) 12
    • Expandable Battery Runtime Runtime is expandable with any number of user supplied wet or gel type batteries
    • DC System Voltage (VDC) 12
    • Battery Charge 14A/55A (selectable)
    • Front Panel LEDs Set of 6 LEDs offer continuous status information on load percentage (6 levels reported) and battery charge level (7 levels reported). See manual for sequences.
    • Switches 3 position on/off/remote switch enables simple on/off power control plus "auto/remote" setting that enables distant on/off control of the inverter system when used in conjunction with included External switch for wired remote control of APS unit APSRM4 ac
    • AC Suppression Joule Rating 760
    • Shipping Dimensions (hwd / in.) 12.5 x 11 x 10.75
    • Shipping Dimensions (hwd / cm) 21.75 x 27.94 x 27.31
    • Shipping Weight (lbs.) 24.8
    • Shipping Weight (kg) 11.2
    • Unit Dimensions (hwd / in.) 7 x 8.75 x 9
    • Unit Dimensions (hwd / cm) 17.78 x 22.23 x 22.86
    • Unit Weight (lbs.) 23.2
    • Unit Weight (kg) 10.5
    • Cooling Method Multi-speed fan
    • Material of Construction Polycarbonate
    • Form Factors Supported Mounting slots enable permanent placement of inverter on any horizontal surface (see manual for additional mounting information)
    • Relative Humidity 0-95% non-condensing
    • Transfer Time (Line Power to Battery Mode) 16.6 milliseconds (typical - compatible with many computers - verify transfer time compatibility of loads for UPS applications)
    • Low Voltage Transfer to Battery Power In AC "auto" mode, inverter/charger switches to battery mode as line voltage drops to 75V (user adjustable to 85, 95, 105V - see manual)
    • High Voltage Transfer to Battery Power In AC "auto" mode, inverter/charger switches to battery mode as line voltage increases to 145V
    • Load Sensing Optional load sense function enables automatic inverter shutoff and startup as connected equipment is powered off and on. Front panel load sense potentiometer can be set to shutoff or turn on inverter power in response to loads of any level, up to 150 watts.
    • Remote Control Capability Yes
    • TVSS Grounding Yes, includes front panel grounding lug
    • Certifications Tested to UL458 (USA) and CAN/CSA-C22.2 No. 107.1-01 (Canada) Also meets KKK-A-1822 (ambulance).
    • Product Warranty Period (U.S. & Canada) 30-month limited warranty
    • Product Warranty Period (International) 1-year limited warranty
    • Product Warranty Period (Mexico) 30-month limited warranty
    • Product Warranty Period (Puerto Rico) 30-month limited warranty
     
  • Warranty:

    • 30-month limited warranty
     
  • GTIN:

    0037332121677
     

EMS1250UL - Required Accessories

    California Residents:
    WARNING:
    Cancer and Reproductive Harm - www.P65Warnings.ca.gov