Evertz 5600MSC-2PS-GP-HTG Combination Master Sync Pulse Generator / Master Clock

ITEM #: EVZ-5600MSC2PSGP MFG #: 5600MSC-2PS-GP-HTG

Primary Image
  • Product Image Thumbnail 1 of 2
  • Product Image Thumbnail 2 of 2

This item is no longer available.
Ask a Markertek Expert if you need assistance finding an appropriate substitute.

(800) 522-2025Email

Items similar to the EVZ-5600MSC2PSGP

5600MSC-2PS-GP-HTG - Overview

The 5600MSC and 5601MSC Master Sync and Clock Generators are both a broadcast quality, master sync pulse generator (SPG) and a master clock. Each provides all of the synchronizing signals needed in a 21st century TV station or post production facility at the same time as solving the problem of locking the in-house master clock system to the master video sync pulse generator.

A high stability, temperature controlled oscillator, provides both the 5600MSC and 5601MSC with better than 1.0x10-8 (or 0.01ppm) frequency reference. The free running drift of this 10MHz reference will be less then 0.1Hz (which amounts to less than one millisecond time drift per day). This guarantees that any frequency drift, with time and temperature, will be within the tolerances expected from the best SPGs or master clocks available in the industry. Both the 5600MSC and 5601MSC may also be referenced to an external 5MHz or 10MHz master oscillator if higher stability is required. Both the SPG and the Master Clock section of the 5600MSC or 5601MSC may be referenced to high stability time and frequency standards present in the Global Position System (GPS) by adding the GPS option (+GP). The 5601MSC may also be referenced to high stability time and frequency standards present in the Global Navigation Satellite System (GLONASS) by adding the GPS/GLONASS option (+GPSG).

The SPG section of both 5600MSC and 5601MSC provides six timeable reference outputs. These six BNC outputs may be configured to provide independently timed color black (black burst) outputs or independently timed HDTV tri-level sync outputs. Each color black output can optionally carry vertical interval time code (VITC) on a user specified set of lines. Additionally, each output can provide 10MHz, 5MHz, PAL Subcarrier, NTSC Subcarrier, 1 PPS, 1/1.001 PPS, 6/1.001 PPS, PAL color frame pulse and 48kHz wordclock.

When referenced to the optional GPS receiver, the start of the NTSC four field sequences, or the PAL 8 field sequence, will coincide with a specific point in the GPS code. In this way, by referencing all the 5600MSCs (or 5601MSCs) in a system to GPS, they will all be automatically locked to each other. This is ideal for applications requiring remote facility frequency, phase and time locked! GPS heads may be remoted from the unit with standard 50ft. cables included or optional 100ft. & 400ft. weatherproof cables. For remote GPS head requirements of greater than 400ft. or fiber optic isolation, GPS Data Fiber Transmitters & Receivers are also available (7707GPS-DT, 7707GPS-DR).

  • Features:

    • 6 independently timeable programmable reference outputs
    • Bi-level or Tri-level outputs selectable
    • 2 Independent LTC Time Code outputs
    • LTC Input (optional on 5600MSC, standard on 5601MSC)
    • Reference loop input for video and 10MHz/5MHz references
    • GPS option for frequency and time reference (GLONASS option for 5601MSC)
    • NTP option for time reference
    • 3.58/4.43/5MHz frequency reference output (only on 5601MSC)
    • 10MHz frequency reference output
    • Wordclock output (optional on 5600MSC, standard on 5601MSC)
    • Output frequency stability guaranteed better then 1.0 x 10-8 (or 0.01ppm)
    • Optional modem for time reference dial up
    • 2 GPS based units will be in time and phase even when remotely separatedby miles
    • Optional test generators available are (refer to ordering options):
    • Composite Video
    • AES/DARS
    • Analog Audio Tones
    • SD SDI
    • HD SDI
    • 3GB/s (only on 5601MSC)
    • Optional Network Time Protocol (NTP) server support (NTP requires a time reference shuch as GPS/GLONASS, modem, VITC, LTC or SNTP. GPS/GLONASS is the recommended reference)
    • For 5600MSC, 16 character Alpha-numeric display, with 20 pushbuttons
    • For 5601MSC, dual 6 line x 16 character Alpha-numeric display, with 10 pushbuttons
    • Rack mountable
    • Optional redundant power supply (redundant power hot-swappable only on 5601MSC)
    • Automatic changeover units available for dual redundant systems applications
    • Compatible with Dual GPS Data Fiber Receivers & Transmitters
    • 2 factory presets and 3 user presets available
    • VITC reader on reference input for time reference
    • Ten Field Pulse is available on NTSC sync outputs
    • VistaLINK control for device configuration and status monitoring
    • On 5601MSC, all active components are front panel extractable & serviceable
     
  • Specifications:

    • Analog Sync Outputs Standards: SMPTE ST 170 (NTSC-M), ITU-R BT 1700-1 (PAL-B), 625i/48Hz/47.95Hz (Slow-PAL)
    • Analog Sync Outputs Standards: SMPTE ST 274 (1080i/60, 1080i/50,1080p/30, 1080p/30sF, 1080p/25, 1080p/25sF, 1080p/24, 1080p/24sF and the 1/1.001 divisor
    • Analog Sync Outputs Standards: SMPTE ST 296 (720/60, 720p/59.94, 720p/50) 1Hz and 6Hz pulse (and the 1/1.001 divisor versions)
    • Connector: 6 BNC per IEC 61169-8 Annex A
    • Number of Outputs: "6 (2 banks of 3) configured as: 6 colour black (black & burst) - selectable with VITC On/Off or 6 HD tri-level sync or 3 color black (black & burst) and 3 HD tri-level sync
    • All outputs independently timeable"
    • DC Offset: 0V ±0.1V
    • Return Loss: Greater than 40dB up to 5MHz
    • SNR: Greater than 75dB
    • 10MHz Input: 0.5V p-p min level, 75? (Relay Bypass Protected)
    • 10MHz Output: 1V p-p (75? terminated)
    • Connector: BNC per IEC 61169-8 Annex A
    • Signal Type: Sine wave. Harmonics < 40dB typical
    • Long Term Oscillator Stability: Free Running: 0.01ppm
    • LTC Outputs Standrad: SMPTE ST 12-1
    • LTC Outputs Frame Rate: Nominal 24, 25, and 30 (drop frame and non-drop frame)
    • LTC Number of Outputs: 2
    • LTC Connectors: 3-pin male XLR type, Female DB9
    • LTC Output Level: Unpowered: Adjustable, 0.5V to 4.5V p-pPowered: 2V p-p with 11V DC offset to drive downstream 1200 series slave clocks
    • Output Impedance: 66? balanced (unpowered)
    • Rise Time: 40 ±10æs
    • Jitter: Less than 2æs
    • Word Clock Number of Inputs: 2
    • Word Clock Number of Outputs: 2 (function menu selectable)
    • Word Clock Type: Opto-isolated, active low with internal pull-ups to +5 volts
    • Word Clock Connector: 4 pins plus 2 ground pins on 9-pin female D connector
    • Word Clock Signal Level: +5V nominal
    • Electrical Voltage: Auto ranging 100 to 240 Volts AC, 50/60Hz
    • Electrical Configuration: Optional redundant supply available with +2PS option
    • Electrical Power: 90 watts max (all options installed)
    • Dimensions (WxDxH): 48.3 cm x 47.7 cm x 4.5 cm
    • Weight: 3.5 kg
     
  • Item Includes:

    • Redundant power supply
    • GPS Option (includes GPS receiver and 50' weatherproof cable)
    • HD SDI Test Generator with 2 HD SDI test signals & 2 HD SDI black
     

5600MSC-2PS-GP-HTG - Required Accessories

    California Residents:
    WARNING:
    Cancer and Reproductive Harm - www.P65Warnings.ca.gov