    SU2200RTXLCD2U - Overview

    Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters, computer rooms and network closets. Online, double-conversion Uninterruptible Power Supply (UPS) maintains perfectly regulated output power by continuously converting raw AC input to DC, then re-converting output back to AC. Fully regulated sine wave AC output with +/-2% voltage regulation powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Maintains battery-derived AC output during power failures with zero transfer time. Extended runtime options available. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. Network management interfaces support communications via USB, RS-232, contact-closure and optional SNMPWEBCARD network interface. Built-in DB9 port offers both enhanced RS-232 data and basic contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. LED display reports UPS operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. LED/LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode LCD configuration options. Programmable self-test. Fault-tolerant auto-bypass mode. Battery independent restart. Field-replaceable, hot-swappable internal batteries and external battery packs.

    What does Uninterruptible Power Supply (UPS) mean?
    An uninterruptible power supply (UPS) provides nearly instantaneous power when the main utility power source fails, allowing either time for power to return or for the user to shut down the system or equipment normally by closing running computer system applications and using the operating system to shut down the system. The user has between five and 15 minutes to shut down a system normally or bring an auxiliary power source online to restore the power supply. In addition, most UPS systems also work to address power source electrical surges, sag voltage, voltage spikes, frequency instability, noise interference or harmonic distortion from the ideal sinusoidal wave form. If you're concerned about power failures, especially if you've lost work on your computer due to power outages in the past, you should buy a UPS. A UPS combines a surge suppressor with a big battery, and has special circuitry that detects a power failure and quickly switches over to run your equipment on its battery. The sole purpose of a UPS is to give you a few minutes at the start of a power failure to do two things:
    -Save your work, and
    -Shut down your computer.
    A UPS is not designed to let you continue to use your computer for hours and hours until the power comes back on. If properly chosen, a UPS will give you 5 to 10 minutes (possibly more) to Save and do an orderly Shutdown.

    • Features:

      • Tripp Lite SU2200RTXLCD2U 2200VA / 2.2kVA / 1800W on-line, double-conversion 2U rack / tower UPS
      • Selectable 100/110/120/127V output (120V factory preset)
      • NEMA 5-20P input, 6 NEMA 5-15/20R and 1 L5-20R outlets
      • Two switched 3-outlet load banks support remote reboot or programmable load shedding options
      • Supports 2% output voltage regulation and zero transfer time in double conversion mode
      • Economy mode option offers enhanced efficiency, reduced power consumption and lower BTU emissions
      • 12 minutes runtime at 50% load (900W) and 4 minutes at 100% load (1800W) with internal batteries
      • BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible) external battery packs available (some configurations require Tripp Lite External Battery Configuration Software)
      • LCD interface reports operating mode plus 9 selectable screens of UPS data (Load % & kW, Load % & kVA, Power factor, Input volts & Hz, Output volts & Hz, Battery volts and charge %, Minutes runtime, Capacity remaining, Kw/hr. consumption)
      • LCD interface also supports 16 screens of UPS configuration and setup options
      • 4 post installation hardware included, Optional 2POSTRMKITWM enables 2 post rack installation, Optional 2-9USTAND enables tower placement
      • Single line TEL / Network surge suppression
      • Electronic bypass maintains utility output during a variety of UPS fault conditions
      • Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
      • Frequency regulation / conversion mode offers generator-compatible frequency correction or conversion of frequency from 50 to 60Hz or 60 to 50Hz
      • USB, RS-232, contact-closure and optional SNMPWEBCARD accessory monitoring options
      • HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
      • Included PowerAlert UPS monitoring software
       
    • Specifications:

      • Nominal Output Voltage(s) Supported: 100V; 110V; 115V; 120V; 127V
      • Nominal Voltage Details: 120V factory-default nominal voltage
      • Frequency Compatibility: 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
      • Output Voltage Regulation (Line Mode): +/- 2%
      • Output Voltage Regulation (Economy Line Mode): +/- 10%
      • Output Voltage Regulation (Battery Mode): +/- 3%
      • Output Receptacles: (6) 5-15/20R; (1) L5-20R
      • Load Management Receptacles: Two switchable three-outlet 5-15/20R load banks
      • Output AC Waveform (AC Mode): Pure Sine wave
      • Output AC Waveform (Battery Mode): Pure Sine wave
      • Rated input current (Maximum Load): 16A
      • Nominal Input Voltage(s) Supported: 100V AC; 110V AC; 115V AC; 120V AC; 127V AC
      • Nominal Input Voltage Description: 120V factory default
      • UPS Input Connection Type: 5-20P
      • Input Circuit Breakers: 30A
      • UPS Input Cord Length (ft.): 10
      • UPS Input Cord Length (m): 3
      • Recommended Electrical Service: 20A 120V
      • Input Phase: Single-Phase
      • Full Load Runtime (min.): 4 min. (1800w)
      • Half Load Runtime (min.): 12 min. (900w)
      • PowerAlert Software: Included
      • Low Voltage Transfer to Battery Power (Setpoint): 100V at full load (90V full load at 100V nominal setting); 70V at 70% load; 55V at 33% load
      • High Voltage Transfer to Battery Power (Setpoint): 150
      • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
      • Green Energy-Saving Features: High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation
       
    • Item Includes:

      • SU2200RTXLCD2U UPS System
      • PowerAlert Software with USB, Serial & EPO cabling
      • 4 post rackmount installation kit
      • Instruction manual
       
    • GTIN:

      0037332168955
       

    SU2200RTXLCD2U - Required Accessories

      California Residents:
      WARNING:
      Cancer and Reproductive Harm - www.P65Warnings.ca.gov